Technical Data
- Power Output: ≤ 60 MW
- Speed: up to 12,000 rpm
- Inlet Pressure: 140 bar(a) / 2,030 psi
- Inlet Temperature: 540 °C / 1,004 °F
- Exhaust Pressure (Backpressure): 20 bar(a) / 290 psi
- Exhaust Pressure (Condensing): 0.7 bar(a) / 10.2 psi
- Controlled Extraction: up to 2 valves, 30 bar(a) / 435 psi, 400 °C / 752 °F
- Uncontrolled Extraction: up to 5 valves, 60 bar(a) / 870 psi
- Design: Horizontally split casing for easy maintenance
- Drive Options: Direct or geared drive to generator or mechanical load
- Compliance: API & ASME standards
Applications
- Combined Cycle Power Plants (CCPP)
- Combined Heat and Power Plants (CHP)
- Concentrated Solar Power Plants (CSP)
- Waste-to-Energy Plants (WtE), e.g. waste incineration
- Biomass Plants
- District Heating Plants
- Chemical and Petrochemical Industry
- Pulp and Paper Mills
- Sugar Industry
- Steel Works
- Mining Industry
- Cement Industry