Close
(0) items
You have no items in your shopping cart.
All Categories
Preferences
Search

CAT DIESEL GENERATOR SET

$0.00
Model: CAT 3512 Serial No.: CAT03512HYAX00376 Engine Hours: 18968 Last TOH: Dec 15, 2022
Please select the address you want to ship to
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options

FEATURES

FUEL/EMISSIONS STRATEGY

  • Low Fuel consumption

DESIGN CRITERIA

  • The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient

FULL RANGE OF ATTACHMENTS

  • Wide range of bolt-on system expansion attachments, factory designed and tested
  • Flexible packaging options for easy and cost effective installation

WORLDWIDE PRODUCT SUPPORT

  • Cat dealers provide extensive post sale support including maintenance and repair agreements
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • The Cat® S•O•SSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

CAT® 3512 TA DIESEL ENGINE

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

CAT GENERATOR

  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency

CAT EMCP 4 CONTROL PANELS

  • Simple user friendly interface and navigation
  • Scalable system to meet a wide range of customer needs
  • Integrated Control System and Communications Gateway

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT

System

Standard

Optional

Air Inlet

•  Single element canister type air cleaner

•  Service indicator

 

Cooling

•  Radiator with guard

•  Coolant drain line with valve

•  Fan and belt guards

•  Cat® Extended Life Coolant

[ ] Radiator duct flange [ ] Jacket water heater

Exhaust

•  Dry exhaust manifold

•  Flanged faced outlets

[ ] Mufflers and Silencers

[ ] Stainless steel exhaust flex fittings

[ ] Elbows, flanges, expanders & Y adapters

Fuel

•  Secondary fuel filters

•  Fuel priming pump

•  Flexible fuel lines

•  Fuel cooler*

[ ] Water separator [ ] Duplex fuel filter

Generator

•  Cat digital voltage regulator (CDVR) with kVAR/PF control, 3-phase sensing

[ ] Oversize & premium generators [ ] Winding temperature detectors [ ] Bearing temperature detectors  [ ] Anti-condensation heaters

Power Termination

•  Bus bar (NEMA or IEC mechanical lug holes)

•  Top cable entry

[ ] Circuit breakers, UL listed, 3 pole with shunt trip,100% rated, manual or electrically operated [ ] Circuit breakers, IEC compliant, 3 or 4 pole with shunt trip, manual or electrically operated

[ ] Bottom cable entry

[ ] Power terminations can be located on the right, left and/or rear as an option.

Governor

•  Woodward 2301A isochronous

[ ] Electronic load sharing governor

Control Panels

•  EMCP 4.2

[ ] Local & remote annunciator modules [ ] Digital I/O Module

[ ] Generator temperature monitoring & protection [ ] Remote monitoring software

Lube

•  Lubricating oil and filter

•  Oil drain line with valves

•  Fumes disposal

•  Gear type lube oil pump

[ ] Oil level regulator [ ] Deep sump oil pan

[ ] Electric & air prelube pumps

[ ] Manual prelube with sump pump [ ] Duplex oil filter

Mounting

•  Rails  -  Engine  /  generator  /  radiator  mounting

•  Rubber anti-vibration mounts (shipped loose)

[ ] Isolator removal

[ ] Spring-type vibration isolator (shipped loose) [ ] IBC Isolators

Starting/Charging

•  24 volt starting motor(s)

•  Batteries with rack and cables

•  Battery disconnect switch

[ ] Battery chargers

[ ] Charging alternator [ ] Oversize batteries   [ ] Ether starting aid

[ ] Heavy duty starting motors [ ] Barring device (manual)

General

•  Right-hand service

•  Paint - Caterpillar Yellow except rails and radiators are gloss black

•  SAE standard rotation

•  Flywheel and flywheel housing - SAE No. 00

[ ] UL 2200

[ ] CSA certification

[ ] CE Certificate of Conformance

SPECIFICATIONS

CAT GENERATOR

Cat Generator

Frame size.......................................................................... 1445

Excitation................................................ Permanent  

Magnet Pitch.............................................................................. 0.6667

Number of poles...................................................................... 4

Number of bearings...................................... Single bearing

Number of Leads.              006

Insulation....................... UL 1446 Recognized Class H with

tropicalization and antiabrasion

- Consult your Caterpillar dealer for available voltages

IP Rating........................................................................... IP23

Alignment.............................................................. Pilot  Shaft

Overspeed capability.......................................................... 150

Wave form Deviation (Line to Line)............................ 002.00

Voltage regulator.............. 3 Phase sensing with selectible volts/Hz

Voltage regulation............Less than +/- 1/2% (steady state)

Less than +/- 1% (no load to full load)

CAT DIESEL ENGINE

3512 TA, V-12, 4-Stroke Water-cooled Diesel Bore........................................................ 170.00 mm (6.69 in)

Stroke..................................................... 190.00 mm (7.48 in)

Displacement.........................................51.80 L (3161.03 in3)

Compression Ratio......................................................... 13.5:1

Aspiration...........................................................................  TA

Fuel System........................................... Direct unit injection

Governor  Type..................................................... Woodward

CAT EMCP 4 SERIES CONTROLS

EMCP 4 controls including:

  • Run / Auto / Stop Control
  • Speed and Voltage Adjust
  • Engine Cycle Crank
  • 24-volt DC operation
  • Environmental sealed front face
  • Text alarm/event descriptions Digital indication for:
  • RPM
  • DC volts
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • Volts (L-L & L-N), frequency (Hz)
  • Amps (per phase & average)
  • ekW, kVA, kVAR, kW-hr, %kW, PF Warning/shutdown with common LED indication of:
  • Low oil pressure
  • High coolant temperature
  • Overspeed
  • Emergency stop
  • Failure to start (overcrank)
  • Low coolant temperature
  • Low coolant level

Programmable protective relaying functions:

  • Generator phase sequence
  • Over/Under voltage (27/59)
  • Over/Under Frequency (81 o/u)
  • Reverse Power (kW) (32)
  • Reverse reactive power (kVAr) (32RV)
  • Overcurrent (50/51) Communications:
  • Six digital inputs (4.2 only)
  • Four relay outputs (Form A)
  • Two relay outputs (Form C)
  • Two digital outputs
  • Customer data link (Modbus RTU)
  • Accessory module data link
  • Serial annunciator module data link
  • Emergency stop pushbutton Compatible with the following:
  • Digital I/O module
  • Local Annunciator
  • Remote CAN annunciator
  • Remote serial annunciator

TECHNICAL DATA

Open Generator Set - - 1500 rpm/50 Hz/400 Volts

DM8222

Low Fuel Consumption

 

Generator Set Package Performance Genset Power rating @ 0.8 pf Genset Power rating with fan

 

1275 kVA

1020 ekW

Fuel Consumption 100% load with fan 75% load with fan 50% load with fan

 

264.6 L/hr

203.2 L/hr

140.8 L/hr

 

69.9 Gal/hr

53.7 Gal/hr

37.2 Gal/hr

Cooling System1

 

0.12 kPa

 

0.48 in. water

Air flow restriction (system)

Air flow (max @ rated speed for radiator arrangement)

1246 m³/min

44002 cfm

Engine Coolant capacity with radiator/exp. tank

286.8 L

75.8 gal

Engine coolant capacity

156.8 L

41.4 gal

Radiator coolant capacity

130.0 L

34.3 gal

Inlet Air

Combustion air inlet flow rate

 

92.0 m³/min

 

3249.0 cfm

Exhaust System

Exhaust stack gas temperature Exhaust gas flow rate

Exhaust flange size (internal diameter)

Exhaust system backpressure (maximum allowable)

 

449.2 º C

231.8 m³/min

203.2 mm

6.7 kPa

 

840.6 º F

8185.9 cfm

8.0 in

26.9 in. water

Heat Rejection

Heat rejection to coolant (total) Heat rejection to exhaust (total) Heat rejection to aftercooler

Heat rejection to atmosphere from engine Heat rejection to atmosphere from generator

 

616 kW

1016 kW

159 kW

115 kW

49.2 kW

 

35032 Btu/min

57780 Btu/min

9042 Btu/min

6540 Btu/min

2798.0 Btu/min

Alternator2

Motor starting capability @ 30% voltage dip Frame

Temperature Rise

 

3087 skVA

1445

125 º C

 

 

 

225 º F

Lube System

Sump refill with filter

 

310.4 L

 

82.0 gal

1  For ambient and altitude capabilities consult your Cat dealer. Air flow restriction (system) is added to existing restriction from factory.

2  UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. Generator temperature rise is based on a 40ºC ambient per NEMA MG1-32.